Dead time correction in coincidence counting of photon pairs
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang M.S. | - |
dc.contributor.author | Lee D.-H. | - |
dc.contributor.author | Lee J. | - |
dc.contributor.author | Lee J.Y. | - |
dc.contributor.author | Choi S.-K. | - |
dc.contributor.author | Park H.S. | - |
dc.date.available | 2021-02-22T15:01:02Z | - |
dc.date.issued | 2008-08 | - |
dc.identifier.issn | 0026-1394 | - |
dc.identifier.issn | 1681-7575 | - |
dc.identifier.uri | https://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/14558 | - |
dc.description.abstract | We describe two methods for evaluating the dead time of a time-to-amplitude converter (TAC). The dead time is obtained by measuring either the corresponding time interval in an oscilloscope trace or the relation between the single count rate and the coincidence count rate. Values for the TAC dead time are obtained in the range from 3.4 νs to 14.3 νs for the two methods with respective standard uncertainties of 2.9 × 10-8 s and 3.3 × 10-9 s. The TAC dead time is applied to the calibration of coincidence-counting measurements of optical transmission and photon-heralding efficiency. © 2008 BIPM and IOP Publishing Ltd. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Institute of Physics Publishing | - |
dc.title | Dead time correction in coincidence counting of photon pairs | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1088/0026-1394/45/4/002 | - |
dc.identifier.scopusid | 2-s2.0-51349114674 | - |
dc.identifier.wosid | 000258299800004 | - |
dc.identifier.bibliographicCitation | Metrologia, v.45, no.4, pp 382 - 388 | - |
dc.citation.title | Metrologia | - |
dc.citation.volume | 45 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 382 | - |
dc.citation.endPage | 388 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | Count rates | - |
dc.subject.keywordPlus | Dead time | - |
dc.subject.keywordPlus | Three term control systems | - |
dc.identifier.url | https://iopscience.iop.org/article/10.1088/0026-1394/45/4/002/pdf | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Sookmyung Women's University. Cheongpa-ro 47-gil 100 (Cheongpa-dong 2ga), Yongsan-gu, Seoul, 04310, Korea02-710-9127
Copyright©Sookmyung Women's University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.