The thermal treatment effect on high-frequency giant magnetoimpedance (GMI) in a glass-coated Co83.2B3.3Si5.9Mn7.6 microwire was investigated. The high-frequency GMI measurement in the form of LC resonators for the microwires annealed at 100 degreesC, 150 degreesC, 200 degreesC, and 250 degreesC for 1 h in a vacuum was performed on samples with 3 mm in width of electrodes and 9 mm in gap length between electrodes in the frequency range 100 MHz-1 GHz. (C) 2004 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
키워드
MAGNETO-IMPEDANCE; WIRES
- 제목
- Thermal treatment effects on high-frequency giant magnetoimpedance in glass-coated Co83.2B3.3Si15.9Mn7.6 microwires
- 저자
- Kim, YS; Yu, SC; Lee, HB; Tuan, A; Kim, CO; Rhee, JR
- 발행일
- 2004-06
- 유형
- Article; Proceedings Paper
- 권
- 201
- 호
- 8
- 페이지