초록
A voltammetric assay of phenol ions was investigated using three electrode systems of graphite pencil working, reference and counter electrodes. Under optimum analytical parameters, square wave stripping working ranges were attained at a mili range of 10~80 mg/L and a micro range of 20~90 ug/L using seawater electrolyte. The developed sensor was applied to tap water and the human body system of a smoker. It was found that the methods can be applied to in vivo fluid or medicinal diagnosis.
키워드
Phenol; voltammetry; Human body; Diagosis; seawater
- 제목
- Diagnostic Assay of Phenol Ions in Human Tissue
- 제목 (타언어)
- Diagnostic Assay of Phenol Ions in Human Tissue
- 저자
- 이수영; 유소담; 홍기원; 이규정; 이진휘
- 발행일
- 2011-12
- 저널명
- 한국응용과학기술학회지
- 권
- 28
- 호
- 4
- 페이지
- 502 ~ 507