상세 보기
- Hong So Jin;
- Jeon Eunsol;
- Kim Min Jung;
- Lee Min Hee
WEB OF SCIENCE
11SCOPUS
9초록
Reductase expression is a potential indicator of cellular pathology. Single-detection systems for reductases have been developed, however, the development of dual-detection systems remain largely unexplored. We rationally designed a dual-lock fluorescent probe that exhibited a high signal-to-noise ratio with a fluorescence Off-On response exclusively for the simultaneous activity of two reductases, NTR and hNQO1, which are overexpressed in cancer hypoxia. The system comprised a naphthalimide fluorophore with dual-lock control mediated by PET and ICT, a trimethyl-locked quinone group sensitive to hNQO1, and a nitrobenzyl carbamate group sensitive to NTR. This study employed a hypoxia model in HeLa cells to demonstrate that our developed dual-lock system detected hypoxia more effectively than single-detection systems. Moreover, it enabled noninvasive real-time monitoring of hypoxia in zebrafish embryos. Consequently, the dual-lock fluorescent probe, which strategically provides a fluorescence response only when both NTR and NQO1 are active, offers a novel diagnostic platform for both in vitro and in vivo applications, effectively detecting hypoxia and monitoring various pathological states.
- 제목
- Dual-Lock System for High Sensitivity and Selectivity in Redox Enzyme Activation and Imaging
- 저자
- Hong So Jin; Jeon Eunsol; Kim Min Jung; Lee Min Hee
- 발행일
- 2025-01
- 유형
- Article
- 권
- 97
- 호
- 2
- 페이지
- 1143 ~ 1150