Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Collaborative Study for the Establishment of National Reference Standard for Molecular Size Distribution Test of Human Immunoglobulin Products

Full metadata record
DC FieldValueLanguage
dc.contributor.authorChan Woong Choi-
dc.contributor.authorWonick Jang-
dc.contributor.authorSun Bo Shim-
dc.contributor.authorHo-Jin Song-
dc.contributor.authorJungHwan Cho-
dc.contributor.authorHyungsil Moon-
dc.contributor.authorSang-Mi Park-
dc.contributor.authorKiwon Han-
dc.contributor.authorKyung Hee Sohn-
dc.date.accessioned2022-04-19T08:53:58Z-
dc.date.available2022-04-19T08:53:58Z-
dc.date.issued2021-06-
dc.identifier.issn0377-9556-
dc.identifier.issn2383-9457-
dc.identifier.urihttps://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/146165-
dc.description.abstractHuman immunoglobulin is a plasma-derived medicinal product that is the second-largest product in the numberof the national lot release in the National Institute of Food and Drug Safety Evaluation (NIFDS), following human serumalbumin. Reference standards are used to confirm the validity of each national lot release test. This study aims to establisha national reference standard (NRS) for the molecular size distribution test applied to immunoglobulin based biologics. 7200 vials, containing 2 mL/vial, were prepared according to the approved manufacturing process for humanimmunoglobulin intended for intramuscular administration. Four laboratories, including the NIFDS, and manufacturers ofhuman immunoglobulin products, participated in this collaborative study, in which a molecular size distribution test wasperformed on candidate vials using size-exclusion high-performance liquid chromatography. Retention of dimer relative tomonomer was 0.851. Relative to a human immunoglobulin (molecular size) biological reference preparation, relativeretention times of monomer and dimer from the candidate vial were 1.001 and 1.000, respectively. This result satisfies therequirements of monographs in the European Pharmacopoeia. Based on a real-time stability evaluation over 24 monthsfollowing manufacture, and a short-term stability evaluation over 14 days after opening, the dimer to monomer relativeretention ratios were found to be distributed within control limits, thereby validating stability. The results of this studysupport registration of this candidate with the NIFDS as the NRS for molecular size distribution test of humanimmunoglobulin products.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisher대한약학회-
dc.titleCollaborative Study for the Establishment of National Reference Standard for Molecular Size Distribution Test of Human Immunoglobulin Products-
dc.title.alternativeCollaborative Study for the Establishment of National Reference Standard for Molecular Size Distribution Test of Human Immunoglobulin Products-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.17480/psk.2021.65.3.223-
dc.identifier.bibliographicCitation약 학 회 지, v.65, no.3, pp 223 - 227-
dc.citation.title약 학 회 지-
dc.citation.volume65-
dc.citation.number3-
dc.citation.startPage223-
dc.citation.endPage227-
dc.identifier.kciidART002737390-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorHuman immunoglobulin-
dc.subject.keywordAuthorNational reference standard-
dc.subject.keywordAuthorMolecular size distribution-
Files in This Item
There are no files associated with this item.
Appears in
Collections
약학대학 > 약학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Jung Hwan photo

Cho, Jung Hwan
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE