Microneedle Vascular Couplers with Heparin-Immobilized Surface Improve Suture-Free Anastomosis Performance
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Dae-Hyun | - |
dc.contributor.author | Lee, Jung Bok | - |
dc.contributor.author | Kang, Mi-Lan | - |
dc.contributor.author | Park, Ji Hwan | - |
dc.contributor.author | You, Jin | - |
dc.contributor.author | Yu, SeongMi | - |
dc.contributor.author | Park, Ju Young | - |
dc.contributor.author | Ryu, Seung Bae | - |
dc.contributor.author | Seon, Gyeung Mi | - |
dc.contributor.author | Yoon, Jeong-Kee | - |
dc.contributor.author | Lee, Mi Hee | - |
dc.contributor.author | Shin, Young Min | - |
dc.contributor.author | Park, Ki Dong | - |
dc.contributor.author | Park, Jong-Chul | - |
dc.contributor.author | Jang, Woo Soon | - |
dc.contributor.author | Kim, Won Shik | - |
dc.contributor.author | Sung, Hak-Joon | - |
dc.date.accessioned | 2022-04-19T09:41:57Z | - |
dc.date.available | 2022-04-19T09:41:57Z | - |
dc.date.issued | 2018-11 | - |
dc.identifier.issn | 2373-9878 | - |
dc.identifier.issn | 2373-9878 | - |
dc.identifier.uri | https://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/146910 | - |
dc.description.abstract | To make up for the shortcomings of the suture-based approach and current coupler devices including long suturing time, exhaustive training, additional mechanical setting, and narrow working windows for size and type of diverse vessel types, a new, suture-free microneedle coupler was developed in this study. The needle shape for improved anastomosis performance and the condition for antithrombotic surface immobilization were determined. In particular, the polymer materials help to maintain healthy phenotypes of main vascular cell types. The performance in rabbit and porcine models of end-to-end vascular anastomosis indicate that this device can serve as a potent alternative to the current approaches. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | American Chemical Societyservice@acs.org | - |
dc.title | Microneedle Vascular Couplers with Heparin-Immobilized Surface Improve Suture-Free Anastomosis Performance | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1021/acsbiomaterials.8b01097 | - |
dc.identifier.scopusid | 2-s2.0-85056269378 | - |
dc.identifier.wosid | 000450373000020 | - |
dc.identifier.bibliographicCitation | ACS Biomaterials Science and Engineering, v.4, no.11, pp 3848 - 3853 | - |
dc.citation.title | ACS Biomaterials Science and Engineering | - |
dc.citation.volume | 4 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 3848 | - |
dc.citation.endPage | 3853 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.url | https://www.webofscience.com/wos/woscc/full-record/WOS:000450373000020 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Sookmyung Women's University. Cheongpa-ro 47-gil 100 (Cheongpa-dong 2ga), Yongsan-gu, Seoul, 04310, Korea02-710-9127
Copyright©Sookmyung Women's University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.