Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Simultaneous Determination and Stability Test of Two Phthalic Anhydride Derivatives, Senkyunolide A and Z-Ligustilide, in the Water Extract of Cnidium Rhizome from Different Geographical Regions and Species Using HPLC-UVD Analysis

Full metadata record
DC FieldValueLanguage
dc.contributor.authorJang, Hyeon Seok-
dc.contributor.authorKang, Kyo Bin-
dc.contributor.authorYoo, Guijae-
dc.contributor.authorKwon, Euna-
dc.contributor.authorYun, Jun-Won-
dc.contributor.authorKang, Byeong-Cheol-
dc.contributor.authorHong, In Kee-
dc.contributor.authorKim, Seung Hyun-
dc.contributor.authorSung, Sang Hyun-
dc.contributor.authorCho, Hyun-Jong-
dc.contributor.authorJang, Young Pyo-
dc.contributor.authorYang, Heejung-
dc.date.accessioned2022-04-19T09:42:32Z-
dc.date.available2022-04-19T09:42:32Z-
dc.date.issued2018-06-
dc.identifier.issn0253-2964-
dc.identifier.issn1229-5949-
dc.identifier.urihttps://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/146924-
dc.description.abstractCnidium rhizome from Cnidium officinale Makino and Ligusticum chuanxiong Hort (Umbelliferae) is traditionally used to treat pain in East Asian countries. Senkyunolide A and Z-ligustilide are phthalic anhydride derivatives that are the bioactive components of cnidium rhizome and chemical markers of the two species; they are also susceptible to external stimuli. In this study, we developed a method to identify two chemical markers using high-performance liquid chromatography (HPLC) with an ultraviolet detector (UVD); the contents of senkyunolide A and Z-ligustilide in cnidium rhizome from different regions were quantified. The stabilities of the compounds were tested at two different temperatures over 12 months. An HPLC-UVD system was used to identify and quantify senkyunolide A and Z-ligustilide in 10 C. officinale samples and 6 L. chuanxiong samples from China and Korea. The long-term stability of the C. officinale samples in dark conditions at 4 and 25 degrees C was also tested. The calibration curves for the two chemical markers showed high linearity (R2 = 1.0000), the precision was high (relative standard deviation (RSD) <4.17%), and the recoveries were within the range of 95-105%. The contents were mostly independent of the geographical origin and species, and >10% of the compounds degraded after storage at-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherWILEY-V C H VERLAG GMBH-
dc.titleSimultaneous Determination and Stability Test of Two Phthalic Anhydride Derivatives, Senkyunolide A and Z-Ligustilide, in the Water Extract of Cnidium Rhizome from Different Geographical Regions and Species Using HPLC-UVD Analysis-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1002/bkcs.11471-
dc.identifier.scopusid2-s2.0-85046737291-
dc.identifier.wosid000434351200013-
dc.identifier.bibliographicCitationBULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.39, no.6, pp 784 - 788-
dc.citation.titleBULLETIN OF THE KOREAN CHEMICAL SOCIETY-
dc.citation.volume39-
dc.citation.number6-
dc.citation.startPage784-
dc.citation.endPage788-
dc.identifier.kciidART002352571-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorCnidium officinale-
dc.subject.keywordAuthorHigh-performance liquid chromatography with an ultraviolet detector-
dc.subject.keywordAuthorLigusticum chuanxiong-
dc.subject.keywordAuthorSimultaneous determination-
dc.subject.keywordAuthorSenkyunolide AZ-ligustilide-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/10.1002/bkcs.11471-
Files in This Item
Appears in
Collections
약학대학 > 약학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Kyo Bin photo

Kang, Kyo Bin
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE