Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

동적 모사를 이용한 에탄 분리탑의 플레어 용량 예측에 관한 연구Study on the Flare Load Estimation of the Deethanizer using Dynamic Simulation

Other Titles
Study on the Flare Load Estimation of the Deethanizer using Dynamic Simulation
Authors
박경태원왕연신동일
Issue Date
Oct-2014
Publisher
한국화학공학회
Keywords
Deethanizer; Dynamic simulation; Dynsim; Flare load estimation
Citation
Korean Chemical Engineering Research(HWAHAK KONGHAK), v.52, no.5, pp 613 - 619
Pages
7
Journal Title
Korean Chemical Engineering Research(HWAHAK KONGHAK)
Volume
52
Number
5
Start Page
613
End Page
619
URI
https://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/147265
DOI
10.9713/kcer.2014.52.5.613
ISSN
0304-128X
2233-9558
Abstract
화학 공장에서 플레어 시스템은 공장의 안전에 지대한 영향을 주는 아주 중요한 요소이다. 만약, 플레어 시스템이필요보다 작게 설계 된다면, 위급 상황 발생 시 끔찍한 사고를 유발할 수 있다. 반면, 플레어 시스템이 필요보다 크게설계하게 된다면 공장을 건설하는데 드는 비용의 증가를 피할 수가 없게 된다. 따라서, 산업계에서는 적절한 플레어 시스템의 설계를 위해 정확한 플레어 배출량을 예측하고자 오랫동안 노력해왔다. 미국석유협회에서는 플레어 배출량 계산을 위한 가이드라인을 제시하였고, 많은 설계 회사들은 정상상태 열 및 물질 수지식을 이용한 방법을 개발하여 플레어 배출량을 예측해 왔다. 하지만, 이러한 방법들은 많은 보수적인 가정들 하에 플레어 배출량을 계산하여 필요보다 크게 설계, 막대한 비용을 초래할 수 있다. 본 연구에서는 기존 방법들이 가지는 문제들을 해결하기 위해 공정제어가 포함된 동적 모사를 통해 플레어 배출량을 계산하는 새로운 절차를 제시하였고, 이 절차에 따라 에탄 분리탑의 배출량을성공적으로 예측함으로써 절차의 효용성을 증명하였다.
A flare system is a very important system that crucially affects on the process safety in chemical plants. If a flare system is designed too small, it cannot prevent catastrophic accidents of a chemical plant. On the other hand, if a flare system is designed too large, it will waste resources. Therefore, reasonable relief load estimation has been a crucial issue in the industry. American Petroleum Institute (API) suggests basic guidelines for relief load estimation, and a lot of engineering companies have developed their own relief load estimation methods that use an unbalanced heat and material method. However, these methods have to involve lots of conservative assumptions that lead to an overestimation of relief loads. In this study, the new design procedure for a flare system based on dynamic simulation was proposed in order to avoid the overestimation of relief loads. The relief load of a deethanizer process was tested to verify the performance of the proposed design procedure.
Files in This Item
Go to Link
Appears in
Collections
공과대학 > 화공생명공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Kyungtae photo

Park, Kyungtae
공과대학 (화공생명공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE