Detailed Information

Cited 0 time in webofscience Cited 4 time in scopus
Metadata Downloads

Development of a Bendable Outsole Biaxial Ground Reaction Force Measurement System

Full metadata record
DC FieldValueLanguage
dc.contributor.authorPark, Junghoon-
dc.contributor.authorKim, Sangjoon Jonathan-
dc.contributor.authorNa, Youngjin-
dc.contributor.authorKim, Yeongjin-
dc.contributor.authorKim, Jung-
dc.date.available2021-02-22T05:46:45Z-
dc.date.issued2019-06-
dc.identifier.issn1424-8220-
dc.identifier.issn1424-3210-
dc.identifier.urihttps://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/3013-
dc.description.abstractWearable ground reaction force (GRF) measurement systems make it possible to measure the GRF in any environment, unlike a commercial force plate. When performing kinetic analysis with the GRF, measurement of multiaxial GRF is important for evaluating forward and lateral motion during natural gait. In this paper, we propose a bendable GRF measurement system that can measure biaxial (vertical and anterior-posterior) GRF without interrupting the natural gait. Eight custom small biaxial force sensors based on an optical sensing mechanism were installed in the proposed system. The interference between two axes on the custom sensor was minimized by the independent application of a cantilever structure for the two axes, and the hysteresis and repeatability of the custom sensor were investigated. After developing the system by the installation of force sensors, we found that the degree of flexibility of the developed system was comparable to that of regular shoes by investigating the forefoot bending stiffness. Finally, we compared vertical GRF (vGRF) and anterior-posterior GRF (apGRF) measured from the developed system and force plate at the same time when the six subjects walked, ran, and jumped on the force plate to evaluate the performance of the GRF measurement system.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleDevelopment of a Bendable Outsole Biaxial Ground Reaction Force Measurement System-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/s19112641-
dc.identifier.scopusid2-s2.0-85068469917-
dc.identifier.wosid000472133300219-
dc.identifier.bibliographicCitationSENSORS, v.19, no.11-
dc.citation.titleSENSORS-
dc.citation.volume19-
dc.citation.number11-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusPEDAR MOBILE SYSTEM-
dc.subject.keywordPlusTREADMILL-
dc.subject.keywordPlusFOREFOOT-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusSTIFFNESS-
dc.subject.keywordPlusWALKING-
dc.subject.keywordAuthorground reaction force-
dc.subject.keywordAuthorbiaxial force sensor-
dc.subject.keywordAuthorreflective photomicrosensor-
dc.subject.keywordAuthoroutsole system-
dc.subject.keywordAuthorforefoot bending stiffness-
dc.identifier.urlhttps://www.mdpi.com/1424-8220/19/11/2641-
Files in This Item
Go to Link
Appears in
Collections
공과대학 > 기계시스템학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Na, Young Jin photo

Na, Young Jin
공과대학 (기계시스템학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE