Detailed Information

Cited 0 time in webofscience Cited 5 time in scopus
Metadata Downloads

Crisscross-designed piezoresistive strain sensors with a cracked microtectonic architecture for direction-selective tensile perception

Authors
Jang, HayeongBaek, SeolheeChoi, GiheonOh, SeungtaekLim, Ho SunJang, YunseokLee, Hwa Sung
Issue Date
Nov-2018
Publisher
ROYAL SOC CHEMISTRY
Citation
JOURNAL OF MATERIALS CHEMISTRY C, v.6, no.41, pp 11170 - 11177
Pages
8
Journal Title
JOURNAL OF MATERIALS CHEMISTRY C
Volume
6
Number
41
Start Page
11170
End Page
11177
URI
https://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/4179
DOI
10.1039/c8tc02321b
ISSN
2050-7526
2050-7534
Abstract
Flexible strain sensors are a key component of electronic skin (e-skin), a technology that is currently receiving considerable research attention with a view to future applications ranging from human healthcare monitoring to robotic skins and environmental risk detection. Here, we developed a highly sensitive, simple, and low-cost piezoresistive strain sensor, which acted as a flexible reactive resistor with a cracked microtectonic architecture that could be fabricated over a large area. In particular, our strain sensor recognizes the direction of tensile stimulation through its rational crisscross electrode design, allowing it to overcome some of the shortcomings of traditional flexible strain sensors. Under a given stress, the strain sensor developed here showed a variation in the relative resistance (Delta R/R-0) of up to 24-fold depending on the direction of the applied stress. For example, application of a 1% strain changed Delta R/R-0 by 0.11 when the strain was applied parallel to the direction of current flow, but by only 0.012 when the strain was applied perpendicular to that direction. Similarly, a 5% strain changed Delta R/R-0 by 0.85 and 0.062, and a 20% strain changed Delta R/R-0 by 2.37 and 0.098, depending on whether the strain was applied parallel or perpendicular to the current flow, respectively. In addition, Delta R/R-0 varied approximately linearly as a function of the strain over the operational range. The results thus show that the proposed sensor is sensitive to the direction in which an external stress is applied. Finally, we demonstrated that our sensor could be used to detect the bending of a human finger.
Files in This Item
Go to Link
Appears in
Collections
공과대학 > 화공생명공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Ho Sun photo

Lim, Ho Sun
공과대학 (화공생명공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE