Biological monitoring of bisphenol A with HLPC/FLD and LC/MS/MS assays

Authors
Yi, BitnaKim, ChangsungYang, Mihi
Issue Date
1-Oct-2010
Publisher
ELSEVIER
Keywords
Bisphenol A; Biological monitoring; HPLC/FLD; LC/MS/MS; Breast milk
Citation
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, v.878, no.27, pp 2606 - 2610
Pages
5
Journal Title
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
Volume
878
Number
27
Start Page
2606
End Page
2610
URI
https://scholarworks.sookmyung.ac.kr/handle/2020.sw.sookmyung/13110
DOI
10.1016/j.jchromb.2010.02.008
ISSN
1570-0232
1873-376X
Abstract
Biological monitoring is a necessary process for risk assessment of endocrine disrupting chemicals (EDCs), particularly, bisphenol A (BPA), in breast milk, because its human risks are not clear yet, and infants, who feed on breast milk, are highly susceptible for EDCs. Concerning biological monitoring of BPA, the HPLC/FLD has been widely used before the LC/MS/MS. However, there was no report, which simultaneously evaluated the two methods in real analyses. Therefore, we analyzed BPA with LC/MS/MS and HPLC/FLD in human breast milk and conducted comparison of two methods in analyzed BPA levels. After establishing optimal condition, e.g. linearity, recovery, reproducibility and free BPA system, we analyzed BPA levels in human breast milk samples (N=100). The LOQs were similar in the two methods, i.e. 1.8 and 1.3 ng/mL for the HPLC/FLD and LC/MS/MS assays, respectively. There were strong associations between total BPA levels with the two methods (R-2 = 0.40, p<0.01), however, only 11% of them were analyzed as similar levels with 15% CVs. In addition, the detection range of BPA was broader in the HPLC method than the LC/MS/MS method. However, the BPA levels in the HPLC/FLD analysis were lower than those in the LC/MS/MS analysis (p<0.01). Thus, the differences in BPA levels between the two methods may come from mainly over-estimation with the LC/MS/MS method in low BPA samples and some of poor resolution with the HPLC/FLD in high BPA samples. (C) 2010 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
약학대학 > 약학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Mi Hi photo

Yang, Mi Hi
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE